Welcome to GentExpert. You will have to register before you have full access and be able to post: click the register link above to proceed. Registration is only available to Gent Approved System Integrators. For your access to be approved, you will need to add your Company email address and/or you Gent Engineering Code. On this page you can read or download V Fit Treadmill Pst 04 User Manual in smart treadmill user manual life fitness gent fire alarm 3260 04 user manual. Gent Fire Alarm Installation Manual. Gent Vigilon Vigilon installation manual, Gent Vigilon. Call Point Range is designed to t32 2 zone fire alarm panel. GENT Xenex range of 1,2,4 and 8 zone fire Control and Repeat panels. 14112-08 Manual call point (surface) 470R n/a As per detectors.
• Installation instructions Vigilon Compact panel based Fire detection and alarm system. • To remove an S-Quad Distributed alarm device load To fi t an S-Quad Lumped alarm device load To fi t a dust cover Vigilon Loop Diagnostic tool To remove a dust cover Typical Vigilon Compact System Vigilon compact parts Vigilon Compact panel. • Vigilon COMPACT fire system Preface Abbreviations This is the third issue of the Installation Alternating current instructions for the Vigilon Compact panel Direct current having 2Km loop card. It covers the End of line approval of 60hz mains frequency, battery charge current data and fi. • Installation Notes As fi tted drawings The power-up of the control panel The installer should acquire site specifi c information from the interested parties, and commissioning of the system is for details on the location of products done by the Servicing organisation. For installation. • Vigilon COMPACT fire system Earth continuity Local Manual Call Point All earth connection points should To comply with the requirements of be clean to provide a good electrical EN54-2: 1997 a conventional manual call conductivity path.
Vray keygen download for idm. CPU & GPU RENDERING MODES VRay for Sketchup 2018 includes two powerful renderers in one.
To maintain the earth point must be installed near the Control continuity: all earth leads and fi. • Local Manual Call Point EN54 information Optional functions with requirements of European standard The Control panel complies with the requirements of EN54-2: 1997. In addition to the basic requirements of the standard the panel conforms to the following optional clauses: Clause Description.
• Vigilon COMPACT fire system System wiring If instructed, the installer may need to terminate as well as connect the cables to the appropriate terminal blocks. Download iveco power 2008 keygen - free download software 2016. Cable separation Where the outgoing and return cables of a loop circuit covers more than the equivalent of one zone they must not run together, for example, either close to the Control Panel or in a service duct. • Requirements of cables Cables Mains Supply cable The mains supply cable must be a Requirements of cables standard fi re resisting type and should The British Standard meet PH30 classifi cation, such as BS 5839 Part 1: 2013 Code of standard or enhanced cable. • Vigilon COMPACT fire system Enhanced loop cables Loop cables Approved cables for loop wiring There is a maximum limit (EMC Compliant) of 2Km loop cable usage Draka Firetuf FT120 Enhanced - allowed per loop circuit. FTPLUS2EH1.5RD This maximum limit is the. • Network cables Prysmian (formally Pirelli) FP Plus* 1.2Km maximum Panel to Panel or Panel to Network node cable distance The cables marked * utilise 3 Cores each having 1.5mm cross laminated aluminium tape with a section area tinned drain wire for electrostatic screening. • Vigilon COMPACT fire system Belden TR No.